kVA (kilovolt-ampere)

Apparent power — the unit used to rate transformers and generators. kVA = kW ÷ power factor.

Transformer kVA calculator
Supply frequency (50 Hz / 60 Hz)

The number of AC cycles per second in a power network: 50 Hz in Thailand, the UAE and the Maldives, 60 Hz in Saudi Arabia. Transformers and motors are rated for one of them.

Exporting to Saudi Arabia
Power factor

The ratio of real power (kW) to apparent power (kVA), between 0 and 1. Motors and other inductive loads lower it; capacitor banks raise it.

Power factor calculator
Reactive power (kVAR)

Power that inductive loads such as motors draw to build their magnetic fields, in kilovolt-amperes reactive. It does no useful work but adds to the current in cables and transformers; a capacitor bank supplies it on site.

Power factor calculator
Demand factor

The share of the connected load expected to run at the same time. It turns connected load into maximum demand when sizing transformers and feeders.

Full-load current

The current a motor draws at its rated output and voltage, stated on its nameplate. For a three-phase motor it depends on efficiency and power factor as well as on kW.

Motor current calculator
Starting current (IA/IN)

The current an induction motor draws while it starts direct on line, several times its rated current. Data sheets give it as a ratio of the rated current; star-delta starting, soft starters and drives reduce it.

Motor current calculator
No-load and load losses

The two losses of a transformer: no-load loss in the core, drawn whenever it is energised, and load loss in the windings, which rises with the square of the current. Quotations and test reports state both in watts.

Transformer loss calculator
Oil-immersed transformer

A transformer whose core and windings sit in insulating oil, which also carries the heat away. Common in outdoor substations and at higher ratings.

Oil-immersed or cast-resin
Cast-resin transformer

A dry-type transformer with its windings cast in epoxy resin, so there is no liquid to leak or burn. Often chosen for indoor rooms in buildings, hotels and hospitals.

Oil-immersed or cast-resin
CSP transformer

Completely self-protected transformer — a pole-mounted distribution transformer with its protection built in, for overhead distribution networks.

Transformers
Vector group (Dyn11)

How a three-phase transformer’s windings are connected, and the phase shift between them. Dyn11 — delta primary, star secondary with neutral, 30° shift — is common for distribution.

ONAN

The cooling code of an oil-immersed transformer cooled without pumps or fans: oil natural, air natural.

MDB (main distribution board)

The main low-voltage switchboard of a building. It is fed from the transformer and feeds the sub-distribution boards.

ACB and MCCB

Air circuit breaker and molded-case circuit breaker — low-voltage breakers that protect circuits against overload and short circuit. ACBs serve the largest currents, such as main incomers.

Switchgear
RMU (ring main unit)

Compact, enclosed medium-voltage switchgear that connects a substation to a cable ring and switches or protects its transformer.

Switchgear
Short-circuit rating (kA)

The fault current that switchgear or a breaker can withstand or break, in kiloamperes. It must be at least the prospective fault current where the equipment is installed.

Fault current calculator
Impedance voltage (uk)

The voltage, as a percentage of rated voltage, that drives full-load current through a transformer with its secondary short-circuited. It sets the transformer’s fault current: about full-load current × 100 ÷ uk.

Fault current calculator
IEC 61439

The IEC standard series for low-voltage switchgear and controlgear assemblies, such as switchboards and distribution boards, including design verification.

7 terms

Cables

XLPE

Cross-linked polyethylene — cable insulation rated for a conductor temperature of 90 °C in normal use. PVC insulation is usually rated for 70 °C.

Power cables
Armoured cable

A cable with steel wires or tapes under the outer sheath — aluminum for single-core cables — for mechanical protection, for example when buried directly.

Fire-resistant cable

A cable designed to keep its circuit working for a stated time in a fire — for fire alarms, emergency lighting, smoke extraction and other life-safety systems.

Voltage drop

The fall in voltage along a cable, caused by its resistance and reactance. Designs keep it within a set percentage so that equipment runs properly.

Voltage drop calculator
IEC 60228

The standard that sets conductor sizes in mm² and the maximum resistance of each size, for insulated cables.

OPGW

Optical ground wire — the earth wire of an overhead power line with optical fibers inside, so it protects the line and carries data at the same time.

Submarine cable

A power or communication cable built to lie on or under the seabed, with armour and water-blocking layers — used to link islands to each other and to the mainland.

Submarine cables

6 terms

Roofing

ASA-uPVC

A roof sheet with a weathering top layer of ASA (acrylonitrile styrene acrylate) over a core of unplasticized PVC.

Roofing
TIS 3586-2566

The Thai Industrial Standard for PVC roof sheets. A TIS license allows the manufacturer to mark its products as meeting the standard.

SABUY PLUS
Flame spread

How far a flame travels across a material’s surface in a standard fire test. The shorter the spread, the better.

Purlin

A horizontal roof member that supports the roof sheets. Its spacing must suit the sheet — 60–100 cm for the SABUY ROOF W1170 profile, per the manufacturer.

Roofing
Cover width

The width of roof one sheet covers once it is side-lapped with the next — less than the sheet’s nominal width. Sheet counts are worked out from it, using the figure in the manufacturer’s datasheet.

Roof sheet calculator
Ridge cap

The cover along the top of a pitched roof, where the two slopes meet.

9 terms

IT and networks

PoE (Power over Ethernet)

Power delivered to cameras, Wi-Fi access points and phones over the same network cable as data, within the switch’s PoE power budget.

Network, Wi-Fi and CCTV
PoE budget

The total power, in watts, that a switch can deliver to all its PoE ports at once. It is usually less than the per-port maximum times the number of ports.

PoE budget calculator
NVR (network video recorder)

A recorder that stores the video streams of IP cameras on its hard disks.

CCTV storage calculator
Bitrate

The data a video stream uses per second, in Mbit/s. It sets both the recording space and the network load.

CCTV storage calculator
H.265 (HEVC)

A video compression standard that typically needs a lower bitrate than H.264 for similar picture quality.

Access point

A device that provides Wi-Fi coverage and connects wireless users to the wired network.

SD-WAN

Software-defined wide area network — links sites over several connections, such as broadband and leased lines, under one central policy.

PROEN Corp
Colocation

Renting rack space, power, cooling and connectivity in a data center for your own servers.

PROEN Corp
System integration (SI)

Designing, installing and configuring separate systems — network, Wi-Fi, CCTV and servers — so that they work together as one.

IT solutions

12 terms

Shipping and documents

Incoterms 2020

Trade rules from the International Chamber of Commerce that set which party pays for, and carries the risk of, each stage of delivery — for example FOB, CIF and DAP.

Shipping to the Maldives
FOB (Free On Board)

The seller clears the goods for export and loads them on board at the named port of shipment. Risk passes to the buyer once the goods are on board.

CIF (Cost, Insurance and Freight)

The seller pays the freight and minimum cargo insurance to the named destination port, but the risk passes to the buyer once the goods are on board at origin.

DAP (Delivered At Place)

The seller delivers the goods to the named place, ready for unloading. The buyer unloads them and handles import clearance and duties.

HS code

The Harmonized System number that classifies goods for customs. It decides the import duty and whether permits are needed.

Bill of lading

The carrier’s document for sea freight: a receipt for the goods, evidence of the contract of carriage and, when negotiable, a document of title.

Certificate of origin

A document that states where goods were made. It can qualify them for a lower duty under a trade agreement.

Packing list

A list of every package in a shipment with its contents, dimensions and weight, used by forwarders and customs.

SABER

Saudi Arabia’s online conformity platform. Regulated products need a product certificate (PCoC) and a certificate for each shipment (SC) through it before customs clearance.

Exporting to Saudi Arabia
PCoC (Product Certificate of Conformity)

The SABER certificate for a regulated product, issued by a conformity assessment body accepted by SASO and valid for one year.

Exporting to Saudi Arabia
MoIAT Certificate of Conformity

The UAE certificate, issued by the Ministry of Industry and Advanced Technology, that a regulated product — for example a low-voltage cable — meets the applicable UAE standard.

Exporting to the UAE
Invoice attestation (UAE)

Certification of an import’s commercial invoice and certificate of origin by the UAE Ministry of Foreign Affairs, done by the importer for imports of AED 10,000 or more.

Exporting to the UAE

General definitions to help read specifications. The project specification, the utility’s requirements and the manufacturer’s documents take precedence.

Start your enquiry.

Send your requirement — our sales team replies by email.

sales@auriforth.com