Key points
- Start with a survey: buildings, users, devices and what each system must do.
- Copper Ethernet links are limited to 100 meters; use fiber between buildings.
- Keep guest, staff, CCTV and building systems on separate network segments.
- Size CCTV storage from camera count, resolution, recording mode and days kept.
- Plan power, surge protection and UPS backup together with the electrical installation.
Start with a site survey
List the buildings, floors and outdoor areas to cover, the number of users and devices, and the systems that must connect — Wi-Fi, CCTV, telephones, point-of-sale, access control and building management. A floor plan and photos of the existing equipment rooms are enough to begin.
Cabling: copper inside, fiber between buildings
Twisted-pair Ethernet cabling, such as Category 6 or 6A, supports links of up to 100 meters from the switch to the device. For longer runs and between buildings — common on resort sites — fiber-optic cable carries the backbone. Fiber is immune to electrical interference, and an all-dielectric cable does not carry surges from one building to another.
Outdoor and underground routes need cable rated for those conditions, and outdoor cabinets need an enclosure rated against dust and water (IP rating) — near the sea, in corrosion-resistant materials. Our guide to network and communication cables compares the cable types and their ratings.
Wi-Fi: coverage and capacity
Plan access points for capacity as well as coverage: a restaurant or meeting room full of guests needs more access points than a corridor of the same size. Walls, glass and water absorb or reflect the signal, so a design made from floor plans and checked on site works better than spacing access points evenly. Newer standards such as Wi-Fi 6 and Wi-Fi 7 serve more devices at once than older ones.
Access points and cameras are usually powered through the network cable (PoE). Check the switch’s total PoE budget, not just its number of ports.
Separate the networks
Guest Wi-Fi, staff systems, CCTV, payment terminals and building systems should run on separate network segments (VLANs) with firewall rules between them. A fault or intrusion in one segment then cannot spread to the others, and guests cannot reach cameras or business systems.
CCTV: cameras, recording and retention
Choose each camera for its view — a wide overview, faces at an entrance or vehicle number plates — and for the light at night. Outdoor cameras near the sea need weatherproof, corrosion-resistant housings.
Recording storage depends on the number of cameras, resolution, frame rate, compression (H.264 or H.265), continuous or motion recording, and the number of days to keep. For example, one 4-megapixel camera recording continuously at 4 Mbit/s uses about 43 GB a day, so 32 cameras kept for 30 days need roughly 40 TB before any redundancy. Try your own figures in the CCTV storage calculator.
In Thailand, CCTV images of people are personal data under the Personal Data Protection Act (PDPA). Good practice is to post notices where cameras record, keep footage only as long as needed, and control who can view or export it.
Power and protection
Network racks, recorders and access points need reliable power. Size the UPS for the load and the backup time you need, add surge protection on incoming power and outdoor cable runs, and earth the equipment racks properly — planned together with the electrical installation.
What to send for a quotation
- Floor plans or a site map, and photos of existing equipment rooms
- Number of users and devices, and the areas that need Wi-Fi
- Number of cameras, indoor or outdoor, and how many days of recording to keep
- Internet links and systems already in place
- Location and target date
See IT solutions and system integration or request a quotation.
General guidance only. Your project specification, applicable codes and standards, utility requirements and the manufacturer’s documents take precedence.