What each kind of data and telecom cable is for — copper LAN cable, coaxial cable, optical fibre and submarine cable — from homes, hotels and factories to poles, ducts and the seabed.

Key points

  • Copper LAN cable carries Ethernet up to 100 m per channel; Category 8 only 30 m.
  • For 10 Gbit/s over the full 100 m, specify Category 6A; Category 6 reaches 37 m, and up to 55 m depending on crosstalk between cables.
  • Optical fibre goes much further: single-mode for kilometres, multimode for short links in buildings and data centres.
  • Fibre to the home uses passive optical networks (PON): one fibre from the exchange is split among many homes.
  • More than 99% of international data traffic travels on about 500 submarine cable systems (ITU).
Where communication cables run: a home, a condominium, a factory and office, a pole, ducts under the road, a landing station and a submarine cable

Simplified drawing, not to scale.

  1. Home: a fibre drop cable reaches the optical network terminal (ONT); Wi-Fi and LAN cable take it from there
  2. Condominium or hotel: a fibre riser carries the network up the building, and each floor connects to it
  3. Factory and office: fibre between buildings, copper LAN cable to the devices, and a network rack
  4. Pole: an aerial fibre cable, and the drop to a house
  5. Underground: ducts and handholes under the road
  6. Cable landing station on the shore
  7. Submarine cable on the seabed, with a repeater

Three families of cable

  • Twisted-pair copper carries electrical signals on pairs of wires twisted together: Ethernet (LAN), telephones, and control and alarm systems.
  • Coaxial cable has one centre conductor inside a screen: television, satellite TV and cable modems (Belden).
  • Optical fibre carries light in glass. It goes much further than copper and is immune to electrical interference (Lapp); long-distance land links and submarine systems use single-mode fibre (ITU-T G.654).

Twisted-pair LAN cable (Ethernet)

A LAN cable has four twisted pairs. Its Category (TIA) or Class (ISO/IEC 11801) states how high a frequency it carries, which decides the speed. Category applies to components such as cable and connectors; Class applies to the finished link.

Category (TIA)Class (ISO/IEC)FrequencyChannel length10 Gbit/s (10GBASE-T)Recognised by TIA
Cat 5eD100 MHz100 mNot supported (2.5 Gbit/s at 100 m)Yes
Cat 6E250 MHz100 m37 m; 37–55 m depends on crosstalk between cablesYes
Cat 6AEA500 MHz100 m100 mYes
Cat 7F600 MHz100 m100 mNo (ISO/IEC only)
Cat 7AFA1,000 MHz100 m100 mNo (ISO/IEC only)
Cat 8I / II2,000 MHz30 m, two connectionsWithin its 30 m channel; also 25/40GBASE-TYes (TIA-568.2-D)
  • Length: the fixed part of a link (permanent link) is at most 90 m, and the whole channel with its patch cords at most 100 m.
  • 2.5 and 5 Gbit/s (IEEE 802.3bz): 2.5 Gbit/s runs on Category 5e and 5 Gbit/s on Category 6, both to 100 m. Category 5e and 6 have no limit for crosstalk between cables, so existing cabling should be checked (TIA TSB-5021).
  • For new work that needs 10 Gbit/s over the full 100 m, use Category 6A.
  • Category 7 and 7A must be S/FTP and use connectors that are not RJ45, so they do not plug into RJ45 ports. Panduit notes that they give the same 10 Gbit/s and PoE performance as Category 6A and do not support 25/40GBASE-T.
  • Wire size: installed cable uses 22–24 AWG conductors (Panduit: Cat 6 23/24 AWG, Cat 6A 23 AWG). TIA-568.2-D also allows thin 28 AWG patch cords; with them the channel shrinks to 96 m (90 m link plus 6 m of cords).
  • The current TIA edition, ANSI/TIA-568.2-E (late 2024), adds a DC resistance unbalance limit: cable that passed the -D edition may not pass -E.

Screened or unscreened

The name before the slash is the screen around the whole cable, the letters after it the screen on each pair: U unscreened, F foil, S braid.

  • U/UTP

    No overall screen, no pair screens

    Four twisted pairs in a jacket, with no screen.

    Usually just called UTP.

  • F/UTP

    Overall foil, unscreened pairs

    A foil wraps all four pairs together.

    Often called FTP.

  • U/FTP

    Foil on each pair

    Each pair has its own foil; there is no overall screen.

    Has a drain wire for the foils (Assmann).

  • S/FTP

    Overall braid, foil on each pair

    A braid around the cable and a foil on every pair.

    Required for Category 7 and 7A.

Power over Ethernet (PoE)

PoE powers access points, cameras and phones through the same LAN cable. The switch (PSE) supplies more than the device (PD) receives, because some power is lost in the cable.

Standard and typeClassAt the switchAt the devicePairs used
IEEE 802.3af, Type 10–315.4 W13 W2
IEEE 802.3at, Type 2430 W25.5 W2
IEEE 802.3bt, Type 35 / 645 / 60 W40 / 51 W4 (classes 1–4 may use 2)
IEEE 802.3bt, Type 47 / 875 / 90 W62 / 71.3 WAlways 4

Cable bundles warm up when they carry power. CommScope (2017) states that installed Category 5 and better supports up to 60 W at an ambient temperature of up to 50 °C; for higher currents, ISO/IEC TS 29125 and TIA TSB-184-A give bundle sizes and recommend Category 6A for four-pair PoE. Size the switch with the PoE budget calculator.

Fire ratings

A cable’s jacket decides where it may be installed. The project specification and the local authority set the rating required; these are the main systems.

North America (NEC)Fire testData cableFire alarm cableTV cable
Plenum (highest)NFPA 262 (UL 910)CMPFPLPCATVP
RiserUL 1666CMRFPLRCATVR
General purposeUL 1685 or CSA FT4CMG, CMFPLCATV
Residential (lowest)VW-1CMX–CATVX
  • Europe (CPR, EN 50575): seven classes from Aca (best) through B1ca, B2ca, Cca, Dca and Eca to Fca. Classes B1ca to Dca add s (smoke), d (flaming droplets) and a (acidity) — for example B2ca-s1a, d1, a1.
  • Low smoke, zero halogen (LSZH): tested to IEC 60332 (flame spread), IEC 60754 (halogen and corrosive gas) and IEC 61034 (smoke density).
  • Thailand: the national digital economy office’s guideline for fibre in buildings recommends flame-retardant LSZH (FR-LSZH) jackets for fibre inside buildings. It is a guideline, not a law.

Coaxial cable

Coaxial cable has a centre conductor inside an insulating layer, surrounded by a screen and a jacket. Television and satellite cable is 75 Ω; 50 Ω cable is a separate family.

Coaxial cable cross-section
CableImpedanceUsed forLoss per 100 m
RG6 (CommScope Series 6, Belden 7916A)75 ΩTelevision, satellite TV (DBS), cable TV and cable modems21.49 dB at 1,000 MHz
RG11 (CommScope Series 11)75 ΩLong drops, where its lower loss helps14.27 dB at 1,000 MHz
LMR-400 (Times Microwave)50 ΩOutdoor PE jacket; -DB water-blocked, -FR riser-rated versions12.8 dB at 900 MHz

For underground runs, CommScope makes flooded drop cable with a PE jacket; the PVC-jacketed versions are for aerial use.

Optical fibre: light in glass

Layers of an optical fibre, stripped back

Not to scale. The buffer is drawn in yellow, the TIA-598 jacket colour for single-mode.

  1. Core: the light travels here; in standard single-mode fibre its mode-field diameter is 8.6–9.2 µm (G.652.D), and multimode cores are 50 or 62.5 µm
  2. Cladding: glass, 125 µm across, which keeps the light in the core
  3. Coating: a protective plastic layer
  4. Tight buffer: 900 µm, used in indoor cables
Single-mode and multimode fibre
  1. Single-mode (OS1a, OS2): a small core carries one path of light, for distances of kilometres
  2. Multimode (OM1–OM5): a larger core carries many paths of light, for short links in buildings and data centres
FibreCore / claddingJacket colour (TIA-598)10GBASE-SR100GBASE-SR4
OM162.5/125 µmOrange33 m–
OM250/125 µmOrange82 m–
OM350/125 µmAqua300 m70 m
OM450/125 µmAqua400 m100 m
OM550/125 µmLime green400 m–
OS1a / OS2 (single-mode)about 9/125 µmYellow10GBASE-LR: 10 km–

Distances are the IEEE figures; manufacturers may quote longer ones for their own fibre. OM5 is designed for several wavelengths between 850 and 940 nm (SWDM). European cables can use other colours — Prysmian’s use violet for OM4 — so check the type printed on the jacket.

Single-mode fibre types (ITU-T)

TypeWhat it isTypical use
G.652.DThe standard single-mode fibre; cable loss at most 0.40 dB/km from 1310 to 1625 nm and 0.30 dB/km at 1530–1565 nmMost networks
G.657.A1 / A2 / B3Bend-insensitive fibre for design radii of 10, 7.5 and 5 mm; A1 and A2 work with G.652.DFibre to the home and inside buildings
G.654.ELarger effective area for 100 Gbit/s and faster coherent systems; at most 0.23 dB/km at 1550 nmLong-distance land backbones
G.654.DLow-loss fibre for high-bit-rate systems; at most 0.20 dB/km at 1550 nmSubmarine systems

Connectors

ConnectorFerruleWhere it is used
LC1.25 mmTelecom and high-speed LAN and storage networks; common with single-mode
SC2.5 mm, push-pullWidely used
ST2.5 mm, bayonetOlder multimode installations
FC2.5 mm, screwOlder single-mode; mostly replaced by SC and LC
MPO / MTP12 or 16 fibres in a rowPre-terminated trunks and parallel 40/100 Gbit/s multimode links

Connector colours: single-mode blue, single-mode angled (APC) green, 62.5 µm beige, OM2 black, OM3/OM4 aqua, OM5 lime (FOA).

Fibre cables for each place

  • Indoor tight-buffered

    IEC 60794-2 · 2–24 fibres

    900 µm buffered fibres with aramid yarn in a flame-retardant LSHF jacket.

    Building and data-centre backbones, in trays or ducts (Prysmian D02b, −20 to +70 °C).

  • Outdoor loose-tube

    IEC 60794-3-10 · TIS 2165-2561

    Fibres loose in tubes (12 per tube in Prysmian's design) round a central strength member, water-blocked with gel or dry swellable tape.

    In ducts, buried or lashed aerial (TIS 2165 covers all three).

  • Armoured loose-tube

    Corrugated steel tape armour

    A loose-tube cable with corrugated steel tape under the jacket.

    Ducts and direct burial, where rodents are a risk (Prysmian TD 24-099, −40 to +70 °C).

  • ADSS

    IEC 60794-4-20 · TIS 2166

    All-dielectric and self-supporting: no metal, aramid yarn carries the weight.

    Hung on poles and along high-voltage lines (example: 120 m spans).

  • Figure-8 aerial

    IEC 60794-3-20

    The fibre cable and a steel messenger wire share one jacket.

    Hung between poles.

  • Flat drop cable

    G.652 / G.657 · e.g. 2.0 × 5.2 mm

    One or two bend-insensitive fibres between two strength members (FRP, aramid or steel).

    The last metres into a house or condominium unit.

  • OPGW

    IEC 60794-4-10 · IEEE 1138

    A stainless-steel tube of fibres stranded with metal wires, forming the earth wire on top of a transmission line.

    Protects the power line from lightning and carries communications.

  • Micro-duct (blown) cable

    G.657.A1 200 µm fibres

    Small, light cables blown into micro-ducts by air: 36 to 864 fibres.

    Dense fibre-to-the-home and 5G networks (Prysmian Sirocco).

Thai standards: TIS 2165-2561 covers outdoor cable for ducts, direct burial and lashed aerial installation (adapted from IEC 60794-3-10), TIS 2166 self-supporting aerial cable, and TIS 2167 cable for lake, river and coastal crossings.

Installing fibre safely

  • Bend radius: for outdoor cables typically at least 10 times the cable diameter at rest and 20 times while being pulled (Prysmian, FOA). Always follow the cable's data sheet: a flat drop cable, for example, is rated 15 times its diameter.
  • Pulling tension: each cable has a limit on its data sheet, for example 2,700 N for an armoured loose-tube cable and 600 N for a flat drop cable.
  • Never look into a fibre or connector. The infrared light is invisible but can damage the eye; offcuts of glass are invisible too and go in a closed, labelled container (Fluke Networks). IEC 60825-2 sets the hazard levels for fibre systems.
  • Inspect and clean connector end-faces before connecting; IEC 61300-3-35 grades dirt, scratches and defects. Inspection does not replace measuring loss.

Fibre to the home (FTTH)

A passive optical network: one fibre from the exchange split to many homes
  1. OLT (optical line terminal) at the provider’s exchange
  2. Passive splitter: needs no power, and shares one fibre among many users (GPON: up to 64 at the physical layer)
  3. ONT/ONU at each home or office, with Wi-Fi and LAN ports
  4. One fibre carries both directions on different wavelengths
GenerationITU-TDown / upWavelengths down / upReach
GPONG.9842.488 / 1.244 Gbit/s1480–1500 / 1260–1360 nm10 or 20 km physical, 60 km logical
XG-PONG.9879.953 / 2.488 Gbit/s1575–1580 / 1260–1280 nmDifferential reach classes of 20 or 40 km (DD20, DD40)
XGS-PONG.9807.110 / 10 Gbit/s1575–1580 / 1260–1280 nm (or the GPON wavelengths)At least 20 km; split at least 1:64

Fibre can continue inside the home. ITU-T G.9940 (fibre to the room, FTTR) links a main fibre unit on the PON to Wi-Fi units in each room, for homes and small businesses.

On poles and under the streets in Thailand

Thailand is tidying the cables on its poles and moving them underground. The Metropolitan Electricity Authority (MEA) regulation of 2023 on communication cables on MEA poles sets these rules:

  • Main cables must be non-metallic optical fibre, at most 18 mm across; drop cables non-metallic fibre, at most 7 mm.
  • Cables must be flame-retardant, and cables made in Thailand must carry the TIS mark.
  • Mounting height: 4.60 m on 8.50 m poles and 5.70 m on poles of 10 m and over; cables across a road at least 5.50 m up.
  • Each operator: at most 3 main cables and 12 drop cables per pole, with no more than 60 drop cables per pole in all, each at most 500 m long.

The cable-tidying plan of the NBTC (the national telecom regulator), titled 2025–2026 in its revised edition, covers 2,519.80 km in Bangkok and its vicinity, and 1,574.482 km in the provinces carried out in 2026 and 2027, cutting each company’s cables on a route to no more than three. MEA planned 29 routes, over 61 km, of communication cable underground in 2024, and National Telecom (NT) has more than 4,600 km of underground conduit for communication cables.

Under the sea

Submarine cables carry more than 99 per cent of international data traffic, on about 500 systems totalling over 1.7 million km (ITU, 2025). In deep water the cable is about as thick as a garden hose; near the shore it is armoured against anchors and fishing gear.

Submarine telecom cables: a lightweight deep-water cable and a double-armoured shallow-water cable

A: deep-water lightweight (LW) cable, about 17 mm. B: double-armoured (DA) cable, about 37.5 mm. Drawn to the same scale, from SubCom SL17 and ASN OALC-4 data.

  1. Optical fibres in a gel-filled tube
  2. High-strength steel wires, two layers, which carry the tension
  3. Copper tube: carries the power for the repeaters and keeps out water and hydrogen
  4. Polyethylene sheath: high-voltage insulation and protection
  5. Steel armour wires: one layer (SA) or two (DA) in shallow water
  6. Polypropylene yarn on the outside
Type (ITU-T G.978)Typical depthDiameter (ASN OALC-4)
LW — lightweightOver 1,000 m17 mm
LWP — lightweight protectedOver 1,000 m23 mm
SA — single armour20–1,500 m28 mm
DA — double armour0–100 m37.5 mm
RA — rock armour0–20 m–
  • Repeaters amplify the light with erbium-doped fibre amplifiers (ITU-T G.977), typically about every 70 km (ICPC and UNEP-WCMC, 2009). Power equipment on shore feeds them a constant direct current through the cable’s copper conductor; Meta notes that power feed equipment in use today is rated up to 18 kV.
  • Fibre pairs: older systems carry up to 8 pairs; 2Africa carries up to 16 and SubCom’s SL17-SDM cable in SEA-ME-WE 6 up to 24.
  • Design life: 25 years (ITU-T G.977, TeleGeography).
  • Burial: near the coast, telecom cables are usually buried 0.5–1.5 m into the seabed, out to water depths of about 1,500 m; deeper, they lie on the seabed without armour (OSPAR, 2023).
  • Faults: about 200 a year; ITU and ICPC (2026) put more than 80% of them down to fishing and anchoring, and other studies give different shares. A repair ship grapples the cable, cuts out the damaged part and splices in new cable (ICPC and UNEP-WCMC, 2009).
  • Fibre: submarine systems use low-loss fibre such as ITU-T G.654.D.

Thailand’s landing stations

Landing pointSystems in service (TeleGeography)
SatunAAE-1, FEA, IAX, MIST, SeaMeWe-4
SongkhlaAAE-1, APG, FEA, SEA-H2X, SJC2, TIS; domestic CSN and TDSCN
Sri Racha (Chon Buri)AAG, ADC; domestic CSN and TDSCN
Phetchaburi, Chumphon, Ko SamuiDomestic TDSCN
RayongMCT

NT lists its stations as Chalee 1 Phetchaburi (domestic), Chalee 2 Songkhla, Chalee 3 Sri Racha and Chalee 4 Satun, with AAE-1 also landing at Pak Bara and Songkhla. The domestic TDSCN (2001, 884 km) and CSN (2013, 1,240 km) cables, both NT’s, run along the Gulf of Thailand.

The UAE and Saudi Arabia

Selected landing pointCable systems (TeleGeography listing)
Fujairah, UAEAAE-1, BBG, EIG, FEA, GBICS/MENA, IMEWE, SeaMeWe-4, SeaMeWe-5, Tata TGN-Gulf, TEAMS, TW1, UAE-Iran
Kalba, UAE2Africa (e& announced the landing in 2024)
Dubai, UAEFALCON, FOG, Tata TGN-Gulf
Jeddah, Saudi Arabia2Africa, AAE-1, EIG, FALCON, FEA, IMEWE, MENA/GBI, PEACE, SAS-1, SAS-2, Saudi Vision, SEACOM/TGN-Eurasia, SeaMeWe-4
Yanbu, Saudi Arabia2Africa, SeaMeWe-5, Saudi Vision
Duba, Saudi Arabia2Africa, Saudi Vision

e& reports about 20 cable systems landing in the UAE, and center3, a subsidiary of Saudi Arabia’s stc, lists 16 subsea systems including five under construction. Listings change as systems open: check the Submarine Cable Map for the current state.

A telecom cable is not a power cable: the current that powers its repeaters is far smaller, and a cable without repeaters carries none (OSPAR). Submarine power cables are covered on the submarine power cables page.

Building, security and control systems

Cable or systemUsed forKey facts
Fire-resistant alarm cable (UK and European standards)Fire alarms, voice alarms, emergency lightingBS 7629-1, BS EN 50200 (30, 60 or 120 minutes), BS 6387 CWZ; Standard and Enhanced grades under BS 5839-1 (Prysmian FP200 Gold and FP PLUS)
RS-485 twisted pair, 120 ΩIndustrial and building controlUp to 32 unit loads; 10 Mbit/s at 12 m, or about 1,200 m at 100 kbit/s; 120 Ω terminations at both ends (Texas Instruments)
PROFINET cableIndustrial EthernetType A fixed, Type B occasional movement, Type C continuous movement such as drag chains; 100 m on copper
M12 X-coded connectorEthernet on machinesCategory 6A, 500 MHz, 10 Gbit/s, IP67 when mated (IEC 61076-2-109)
KNX TP bus cableBuilding automationUp to 64 devices and 1,000 m of cable per line (Siemens, bticino)
HDBaseTVideo, audio, control and power over LAN cableUp to 100 m and 100 W of power (HDBaseT Alliance)
Outside-plant LAN cableBetween buildingsGel-filled, UV-resistant jacket; for direct burial, aerial or duct use (Siemon, −40 to 75 °C)
Aerial telephone cableTelephone networks on polesTIS 2434-2552: 0.4–0.9 mm conductors, up to 3,000 pairs in groups of 25, aluminium screen, PE jacket

Keep data cables away from power cables

Power cables can induce interference in data cables. BS EN 50174-2:2009 sets the separation as A = S × P: S depends on the data cable and the containment, and P on the number of power circuits (for example 0.2 for one to three 20 A circuits and 1.0 for 13 to 15). Values from the 2009 edition — check the current one.

Data cable (segregation class)No containment or plasticOpen metal trayPerforated metal traySolid metal tray
d — Class FA10 mm8 mm5 mm0
c — Class D/E/EA, U/FTP50 mm38 mm25 mm0
b — Class D/E/EA, U/UTP100 mm75 mm50 mm0
a — coaxial300 mm225 mm150 mm0

Hot climates: the UAE and Saudi Arabia

Copper loses more signal as it warms. Above 20 °C, ISO/IEC 11801:2011 shortens the horizontal cable by 0.2% per °C for screened cable, and by 0.4% per °C (20–40 °C) and 0.6% per °C (40–60 °C) for unscreened cable. The earlier TIA-568-C.2 annex, quoted by Fluke Networks, gives these maximum lengths — a separate data set that differs slightly from the ISO/IEC rule:

Ambient temperature20 °C30 °C40 °C45 °C50 °C60 °C
Unscreened cable90.0 m87.0 m84.0 m81.7 m79.5 m75.0 m
Screened cable90.0 m88.5 m87.0 m86.5 m85.5 m83.0 m
  • Design shorter links instead of relaxing the test limits (Fluke Networks).
  • For channels not designed specifically for power delivery, ANSI/TIA-568.2-E Annex H sets a maximum ambient of 45 °C and cable rated for at least 60 °C.
  • Outdoor fibre cables are commonly rated −40 to +70 °C on their data sheets (Prysmian).

Which cable where

General options drawn from the sections above; the project design and the authority’s rules decide.

PlaceOptionsWatch out
HomeFibre drop to the ONT; Category 6 or 6A inside; RG6 for satellite TVCopper links at most 100 m
CondominiumFibre riser with FR-LSZH jacket; LAN cable to each unitBuilding guideline: fibre jackets FR-LSZH
Hotel or resortFibre between buildings; Category 6A to Wi-Fi access points with PoESize the PoE budget; see network, Wi-Fi and CCTV planning
OfficeCategory 6A to desks; OM4/OM5 or single-mode backbone10 Gbit/s at 100 m needs Category 6A
Data centreMPO trunks on OM4/OM5 or single-mode; Category 8 for links up to 30 mCategory 8 reaches only 30 m
FactoryPROFINET Type A/B/C, M12 X-coded, RS-485; fibre where interference or distance is highMatch the cable type to how much it moves
Between buildingsArmoured loose-tube fibre in ducts or buriedBend radius 10× at rest, 20× when pulling
MEA polesNon-metallic fibre, at most 18 mm (drop 7 mm)MEA rules on height and number of cables
Under the seaLightweight cable in deep water, armoured near the shoreEngineered for each system

Checklist: what to specify

  • Cable type: copper category and screen, coaxial type, or fibre type (OM/OS) and fibre count
  • Fire rating or jacket the project requires (for example LSZH, CMR or a CPR class)
  • Indoor, outdoor, duct, direct burial or aerial — and any armour
  • Length per drum and total length; connectors or pre-terminated assemblies
  • Delivery location and target date

Related: IT solutions and system integration and planning network, Wi-Fi and CCTV.

Sources

Compiled in November 2026 from the documents below — standards bodies, regulators, operators and manufacturers. Most standards named on this page are sold copies; their figures here come from these documents. Standards and listings change: check the current edition before use.

General guidance only. Your project specification, applicable codes and standards, utility requirements and the manufacturer’s documents take precedence.

Glossary of terms

Keep reading

Related.

  • Solution

    IT solutions & system integration

    Computer and network systems, communications, CCTV and smart building systems — supplied for organizations and projects in Thailand and exported to the UAE, Saudi Arabia and the Maldives, with installation and integration where included in scope.

    See the solution: IT solutions & system integration
  • IT solutions

    Planning network, Wi-Fi and CCTV.

    A checklist for hotels, resorts, offices and public buildings — from cabling and Wi-Fi coverage to camera storage — so that the systems work together from day one.

    Read the guide: Planning network, Wi-Fi and CCTV.
  • Electrical

    Oil-immersed or cast-resin?

    Both types step voltage down for a building or site. The right choice depends on where the transformer stands, the rating you need and what your utility or specification requires.

    Read the guide: Oil-immersed or cast-resin?
  • Roofing

    Roofing for coastal and island sites.

    Salt air, strong sun and heavy rain are hard on a roof. Here is what to weigh when choosing between coated metal sheet and ASA-uPVC near the sea.

    Read the guide: Roofing for coastal and island sites.